|
|
||||||||
RESEARCH REPORT |
1 Division of Dental Sciences and Biomaterials, Department of Biomedicine, University of Trieste, Via Stuparich, 1, I-34125 Trieste, Italy;
2 Department of SAU & FAL, University of Bologna, Italy;
3 Department of Dental Sciences, University of Tor Vergata, Rome, Italy; and
4 Department of Oral Biology, School of Dentistry Medical College of Georgia, Augusta, GA, USA
* corresponding author, lbreschi{at}units.it
| ABSTRACT |
|---|
|
|
|---|
KEY WORDS: dental bonding systems electric current microtensile bond strength nanoleakage
| INTRODUCTION |
|---|
|
|
|---|
An adhesive application protocol, based on the use of an electric signal to enhance monomer infiltration in dentin, has recently been reported (Pasquantonio et al., 2006). This device (ElectroBond; Seti, Rome, Italy) consists of a handpiece that carries an adhesive-filled disposable sponge. Release of the adhesive is triggered by the electric potential difference between the tooth surface and the adhesive. Similar to an apex locator, the second electrode (i.e., lip clip) is placed intra-orally and connected via an electric circuit that creates an electrical current via a digitally controlled current modulator. The rationale for applying a dentin adhesive under an electric current is to improve adhesive infiltration of the demineralized dentin (Pasquantonio et al., 2006) by altering the surface charges and hydrogen bonding potential of the dentin substrate (Vaidyanatha et al., 2001; Pashley et al., 2003). The efficacy of applying self-etching adhesives under the influence of an electric signal has not been investigated. Since these adhesives contain high concentrations of polar monomers, it is speculated that pronounced dentin surface interactions with an electric current may occur during the self-etching, self-priming process.
This study examined the bonding efficacy and interfacial nanoleakage of 2 simplified self-etch adhesives and a two-step self-etch primer adhesive under the application of an electric current. The null hypothesis tested was that the application of an electric current during the bonding of self-etch adhesives to dentin has no effect on their microtensile bond strengths.
| MATERIALS & METHODS |
|---|
|
|
|---|
The teeth (N = 10 for each group) were bonded with 3 adhesives: a two-step self-etching primer system (Clearfil Protect Bond, Kuraray Medical Inc., Tokyo, Japan), and 2 one-step self-etching systems (Xeno III, Dentsply DeTrey, Konstanz, Germany; and Adper Prompt L-Pop, 3M EPSE, St. Paul, MN, USA). For one half of each tooth, the adhesive was applied with the use of the electric device, ElectroBond ver. 1.2004 (Pasquantonio et al., 2003), which created an electric potential difference between the dentin substrate and the adhesive applicator tip. Voltage was maintained constant with a voltmeter. Each specimen to be bonded was fitted into a wet sponge, to simulate periodontal tissues (Pethig, 1987), and the sponge was subsequently wired to the electric circuit. For the other half of each tooth (control group), the adhesive was applied in the same manner, but with the electric generator switched off. A single-blind study design was used, in which the operator performing the bonding procedure was not aware of the operating state of the electrical device (i.e., switched-on mode or switch-off mode). The electric applicator was used with a continuous brushing motion. For the two-step self-etch primer adhesive, Clearfil Protect Bond, application of both the priming solution and the bonding agent was conducted with the electric device in the switched-on mode in the experimental group, and in the switched-off mode in the control group. A 4-mm-thick layer of microhybrid resin composite (Filtek Z250, 3M ESPE) was incrementally placed over the bonded dentin surface and polymerized for 20 sec.
Microtensile Bond Strength Evaluation
The pulp chamber was bonded with Clearfil Protect Bond, in accordance with the manufacturers instructions, and filled with Filtek Z250. Sticks with surface areas of approximately 0.9 x 0.9 mm were created from each specimen, by means of a low-speed saw under water irrigation. The dimension of each stick was individually measured, with a digital caliper, to the nearest 0.01 mm, and the bonding area was calculated for subsequent bond strength evaluation. The specimens were observed under a stereomicroscope (Stemi 2000-C, Carl Zeiss Jena GmbH, Germany) to avoid the inclusion of sticks containing residual enamel. The sticks were stored in de-ionized water for 24 hrs, and attached to a modified jig for microtensile testing. They were stressed to failure under tension with a universal testing machine at a crosshead speed of 1 mm/min. Failure modes, evaluated by stereomicroscopy at 50X magnification, were classified as cohesive (composite and/or dentin), adhesive, or mixed failure. The number of prematurely debonded sticks per group during specimen preparation was also recorded, but not included in the statistical evaluation. Since values were not normally distributed (Kolmogorov-Smirnof test), we used a Mann-Whitney test to compare the data, with statistical significance set at
= 0.05.
Nanoleakage Evaluation
Two bonded sticks from the center of each bonded specimen were used for nanoleakage evaluation. The specimens were covered with nail varnish, leaving 1 mm2 free of varnish at the interface. They were immersed in a 50 wt% ammoniacal AgNO3 solution prepared according to Tay et al.(2002). After immersion in the tracer solution for 24 hrs, we photodeveloped the specimens to reduce the diamine silver ions ([Ag(NH3)2]+) into metallic silver grains. The silver-impregnated sticks were polished with 1200-grit silicon carbide papers to remove the surface silver deposits. They were dehydrated, dried, and examined uncoated in accordance with the nanoleakage evaluation protocol reported by Suppa et al.(2005), with the in-lens mode of a field emission-scanning electron microscope (FE-SEM; JSM 890, JEOL, Tokyo, Japan) at 7 kV and 1 x 1012 Amp. Images were obtained with both secondary-electron (SEI) and back-scattered (BSI) signals. We also used energy-dispersive x-ray analysis (EDX) to confirm the elemental composition of the observed deposits.
| RESULTS |
|---|
|
|
|---|
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Since dentin is not an ideal component of electric circuits (i.e., it is not a pure capacitor or resistor), the flow of electricity depends upon dentin thickness, the presence of water and solutes (Eldarrat et al., 2003), and the relative humidity of the environment (Krizaj et al., 2004). Eldarrat et al.(2004) showed that resistance and impedance of a dentin surface are related to the presence or absence of a smear layer and its thickness. Etching of the surface and subsequent exposure of the organic matrix in a wet environment increase the electric flow by reducing resistance (Eldarrat et al., 2003). Thus, to ensure consistency of results, we subjected all adhesive applications to the same electrical experimental conditions, regardless of the tooth dimensions. For this reason, preliminary data on the resistance and impedance of tooth specimens were recorded, so that the electric device could be adjusted to electrical values that are compatible with in vivo use (Daskalov et al., 1997; Krizaj et al., 2004).
Since microtensile bond strength was significantly improved in the ElectroBond-assisted technique vs. the control application technique, regardless of the tested adhesives, we had to reject the null hypothesis examined in this study. In particular, simplified adhesives exhibited bond strengths that were almost double those of the control groups, suggesting a potential use of the electric-current-assisted technique during the application of these adhesives. Apart from bond strength enhancement, the electric current also improved the quality of the hybrid layer. This was manifested as a qualitative reduction in the extent of nanoleakage for teeth bonded with the electric-current-assisted technique, particularly for the 2 simplified adhesives, Xeno III and Adper Prompt L-Pop. Considering that extensive nanoleakage was seen when these simplified adhesives were bonded to sound dentin (Tay et al., 2002; Suppa et al., 2005), its reduction should be considered a potential improvement in the bond quality.
Since resin infiltration of self-etch adhesives occurs concomitantly with demineralization of the smear-layer-covered dentin (Van Meerbeek et al., 2005), electric current may influence either of the 2 processes. Since hybrid layers created by the experimental and control techniques were similar in thickness (data not shown), demineralization was unlikely to be affected by the generation of an electric signal. Conversely, the marked reduction in nanoleakage with the electric-current-assisted technique suggests that the latter was involved with the process of resin infiltration. We speculate that 3 mechanisms are potentially responsible for the improved infiltration of self-etch adhesives bonded with the experimental technique. They include a direct electrostatic effect on polar monomers present in the adhesives, modification of dentin matrix wettability, and enhanced water removal.
Polar resin monomers present in the self-etch adhesives can interact with the electric current. Since these molecules diffuse toward the demineralization front during adhesive application, this polarization effect may increase the penetration of polar resin monomers through the smear layer and the underlying sound dentin. Since simplified self-etch adhesives contain higher concentrations of ionic and hydrophilic monomers, they should be more susceptible to the passage of electric currents. This possibly explains their higher bond strength increase over that of the two-step self-etch adhesive, Clearfil Protect Bond.
Enhanced resin infiltration may also be due to transient biophysical modification of the dentin organic matrix when it is exposed to an electric current, with enhancement of the wettability of the dentin surface. Demineralization of the smear layer and underlying intact dentin by acidic resin monomers creates a water-based acidic environment, consisting of a complex polyelectrolyte hydrogel with a diffusion coefficient of ions that approximates the diffusion coefficient of free, unbound water (Comper and Laurent, 1978). Pethig (1987) demonstrated that collagen fibrils are polar, due to the 3.7-Debye dipole moment present in the peptide unit of the triple helix, and to the presence of dipoles derived from the water molecules (Jayasuriya et al., 2003) attached to proteoglycan-associated lateral chains (Breschi et al., 2003). Large glycosaminoglycans that are present in the proteoglycan lateral chains regulate the biophysical properties of the dentin organic matrix, as well as its three-dimensional appearance. Glycosaminoglycans not only have the ability to fill space, they also bind and organize water molecules. Being highly negatively charged and strongly polar, they are strongly influenced by electric signals (Scott, 1988). Thus, proteoglycans assume a fundamental role in determining the properties of the dentin matrix (Perdigão and Lopes, 1999). Since collagen fibrils and proteoglycans are highly polar, they are susceptible to three-dimensional modifications when in electric fields. Electric current may also modify intra- and interfibrillar hydrogen bonds among the collagen fibrils (Jayasuriya et al., 2003) inducing temporary changes in the quaternary protein structure.
Since Adper Prompt L-Pop and Xeno III are more acidic than Clearfil Protect Bond, they expose more dentin organic matrix than does Protect Bond, by more aggressive dissolution of the apatite phase (Van Meerbeek et al., 2005). The piezoelectric characteristics of collagen fibrils may also enable them to alter their three-dimensional arrangement (Marino and Gross, 1989; Jayasuriya et al., 2003). Thus, the application of electric current may induce subtle orientation changes within the organic fibrillar network that favors adhesive infiltration.
Application of an electric current may also increase the water substitution rate by modifying water dipoles, thereby favoring water/solvent exchange during resin infiltration (Pashley et al., 2003; Van Landuyt et al., 2005).
In conclusion, this study reports, for the first time, improvements in bond strengths and reduction in nanoleakage when self-etch adhesives are use in conjunction with an electricity-assisted application technique for bonding to dentin. Further in vivo studies are currently ongoing to validate the potential mechanisms that are proposed for the improvement in resin infiltration that is associated with the use of the ElectroBond-assisted bonding technique.
| ACKNOWLEDGMENTS |
|---|
Received October 7, 2005; Last revision June 21, 2006; Accepted September 22, 2006
| REFERENCES |
|---|
|
|
|---|
Cadenaro M, Antoniolli F, Sauro S, Tay FR, Di Lenarda R, Prati C, et al. (2005). Degree of conversion and permeability of dental adhesives. Eur J Oral Sci 113:525530.[ISI][Medline]
Comper WD, Laurent TC (1978). Physiological function of connective tissue polysaccharides. Physiol Rev 58:255315.
Daskalov I, Indjov B, Mudrov N (1997). Electrical dental pulp testing. Defining parameters for proper instrumentation. IEEE Eng Med Biol Mag 16:4650.[Medline]
Eldarrat A, High A, Kale GM (2003). Age-related changes in cyclic voltammetry and potentiodynamic studies of normal human dentine. J Mater Sci Mater Med 14:979984.[ISI][Medline]
Eldarrat AH, High AS, Kale GM (2004). In vitro analysis of smear layer on human dentine using ac-impedance spectroscopy. J Dent 32:547554.[ISI][Medline]
Hashimoto M, Sano H, Yoshida E, Hori M, Kaga M, Oguchi H, et al. (2004). Effects of multiple adhesive coatings on dentin bonding. Oper Dent 29:416423.[ISI][Medline]
Hashimoto M, Tay FR, Ito S, Sano H, Kaga M, Pashley DH (2005). Permeability of adhesive resin films. J Biomed Mater Res B Appl Biomater 74:699705.[Medline]
Huysmans MC, Verdonschot EH, Rondel P (1995). Electrical conductance and electrode area on sound smooth enamel in extracted teeth. Caries Res 29:8893.[ISI][Medline]
Jayasuriya AC, Scheinbeim JI, Lubkin V, Bennett G, Kramer P (2003). Piezoelectric and mechanical properties in bovine cornea. J Biomed Mater Res A 66:260265.[Medline]
King NM, Tay FR, Pashley DH, Hashimoto M, Ito S, Brackett WW, et al. (2005). Conversion of one-step to two-step self-etch adhesives for improved efficacy and extended application. Am J Dent 18:126134.[ISI][Medline]
Krizaj D, Jan J, Valencic V (2004). Modeling AC current conduction through a human tooth. Bioelectromagnetics 25:185195.[ISI][Medline]
Li HP, Burrow MF, Tyas MJ (2001). The effect of long-term storage on nanoleakage. Oper Dent 26:609616.[ISI][Medline]
Marino AA, Gross BD (1989). Piezoelectricity in cementum, dentine and bone. Arch Oral Biol 34:507509.[ISI][Medline]
Pashley EL, Agee KA, Pashley DH, Tay FR (2002). Effects of one versus two applications of an unfilled, all-in-one adhesive on dentine bonding. J Dent 30:8390.[ISI][Medline]
Pashley DH, Agee KA, Carvalho RM, Lee KW, Tay FR, Callison TE (2003). Effects of water and water-free polar solvents on the tensile properties of demineralized dentin. Dent Mater 19:347352.[ISI][Medline]
Pasquantonio G, Breschi L, Petrone A, inventors (2003). A method and device for preparing the hard structures of teeth for the application of dental restorative materials. US Patent 2003; 6,641,396, Nov 4.
Pasquantonio G, Tay FR, Mazzoni A, Suppa P, Ruggeri A Jr, Falconi M, et al. (2006). Electric device improves bonds of simplified etch-and-rinse adhesives. Dent Mater (in press; e-pub ahead of print).
Perdigão J, Lopes M (1999). Dentin bondingquestions for the new millennium. J Adhes Dent 1:191209.[Medline]
Pethig R (1987). Dielectric properties of body tissues. Clin Phys Physiol Meas 8(Suppl A):512.
Peumans M, Kanumilli P, De Munck J, Van Landuyt K, Lambrechts P, Van Meerbeek B (2005). Clinical effectiveness of contemporary adhesives: a systematic review of current clinical trials. Dent Mater 21:864881.[ISI][Medline]
Scott JE (1988). Proteoglycan-fibrillar collagen interactions. Biochem J 252:313323.[ISI][Medline]
Sunada I (1962). New method for measuring the length of the root canal. J Dent Res 41:375387.
Suppa P, Breschi L, Ruggeri A, Mazzotti G, Prati C, Chersoni S, et al. (2005). Nanoleakage within the hybrid layer: a correlative FEISEM/TEM investigation. J Biomed Mater Res B Appl Biomater 73:714.[Medline]
Tay FR, Pashley DH, Yoshiyama M (2002). Two modes of nanoleakage expression in single-step adhesives. J Dent Res 81:472476.
Tay FR, Hashimoto M, Pashley DH, Peters MC, Lai SC, Yiu CK, et al. (2003). Aging affects two modes of nanoleakage expression in bonded dentin. J Dent Res 82:537541.
Tay FR, Pashley DH, Garcia-Godoy F, Yiu CK (2004). Single-step, self-etch adhesives behave as permeable membranes after polymerization. Part II. Silver tracer penetration evidence. Am J Dent 17:315322.[ISI][Medline]
Vaidyanatha J, Vaidyanathan TK, Yadav P, Linaras CE (2001). Collagen-ligand interaction in dentinal adhesion: computer visualization and analysis. Biomaterials 22:29112920.[ISI][Medline]
Van Landuyt KL, De Munck J, Snauwaert J, Coutinho E, Poitevin A, Yoshida Y, et al. (2005). Monomer-solvent phase separation in one-step self-etch adhesives. J Dent Res 84:183188.
Van Meerbeek B, Van Landuyt K, De Munck J, Hashimoto M, Peumans M, Lambrechts P, et al. (2005). Technique-sensitivity of contemporary adhesives. Dent Mater J 24:113.[ISI][Medline]
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| IADR Journals | Advances in Dental Research ® |
| Journal of Dental Research ® | Critical Reviews (1990-2004) |