Journal of Dental Research

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Butz, F.
Right arrow Articles by Ogawa, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Journal of Dental Research, Vol. 85, No. 6, 560-565 (2006)
DOI: 10.1177/154405910608500616


Biomaterials & Bioengineering

Harder and Stiffer Bone Osseointegrated to Roughened Titanium

F. Butz, H. Aita, C.J. Wang and T. Ogawa*

The Jane and Jerry Weintraub Center for Reconstructive Biotechnology, Division of Advanced Prosthodontics, Biomaterials and Hospital Dentistry, UCLA School of Dentistry, 10833 Le Conte Avenue (B3-087 CHS), Box 951668, Los Angeles, CA 90095-1668, USA

Correspondence: * corresponding author, tack{at}dent.ucla.edu

Mechanisms underlying the beneficial anchorage of roughened titanium implants have not been identified. We hypothesized that the implant surface roughness alters intrinsic biomechanical properties of bone integrated to titanium. Nano-indentation performed on two- and four-week post-implantation bone specimens of rats revealed that bone integrated to acid-etched titanium was approximately 3 times harder than that integrated to the machined titanium, both at the osseointegration interface and at the inner area of the peri-implant bone. The hardness of the acid-etched surface-associated bone was equivalent to that of untreated cortical bone at week 4, while the bone hardness around the machined surface was equivalent to that of the untreated trabecular bone. The elastic modulus of the integrated bone was 1.5 to 2.5 times greater around the acid-etched surface than around the machined surface. Analysis of the data suggests that the implant surface roughness affects the biomechanical quality of osseo-integrated bone, and that the bone integrated to the acid-etched surface is harder and stiffer than the bone integrated to the machined surface.

Key Words: osseointegration • nano-indentation • acid-etching • bone hardness • elastic modulus


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?