Journal of Dental Research, Vol 60, 139-145, Copyright © 1981 by International & American Associations for Dental Research Online Journals
ARTICLES |
D. K. Yoshikawa, C. J. Burstone, A. J. Goldberg and J. Morton
The flexure modulus of elasticity of standard stainless steel orthodontic wires was determined by the use of an iterative finite element technique to be 25.4 x 10(6) psi (175 x 10(3) MN/m2). This technique accounts for the configurational changes in the test specimens due to the relatively large deflection during the cantilever test. Under these conditions, the elementary strength of materials relationships does not accurately describe the flexure characteristics of the wires.
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| IADR Journals | Advances in Dental Research ® |
| Journal of Dental Research ® | Critical Reviews (1990-2004) |